Product Name |
Aluminum core overhead cable |
|
Coductor |
Aluminum Wire ,or ACSR conductors, concentrically stranded |
|
Insulation |
Cross-linked polyethylene(XLPE) insulated |
|
Section |
10-240mm2 |
|
Standard |
GB/T 12527 |
|
Voltage |
0.6/1kv |
|
Application |
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. |
|
OEM/ODM |
Available |
|
Sample |
Free, freight charge prepaid or negotiation |
|
Delivery Detail |
10-20 days after confirming the order |
|
MOQ |
500 meters |
|
Package |
Wooden Durm |

(1)The rated voltage Uo/U is 0.6/1kV.
(2)The maximum rated temperature of cable conductor is 90℃.
(3)Cable shall be laid at no less than -20℃
(4)Minimum allowable bending radius of the cable:
Cable with an outer diameter(D) less than 25mm shall have a diameter no less than 4D.
The outer cable diameter(D) of 25mm and above shall be not less than 6D.
Overhead cable has characters of power-transmitting and strong mechanical. In comparison with bare wire, Overhead cable boasts many advantages, such as,small span in laying, higher safe reliability, better atmosphere aging resistance property. Insulated overhead cable has the priority to be used in urban and rural power-transmitting construction project.
This hot sales electric wire have been sold to Europe, Southeast Asia, Middle East, South Africa, getting good reputations from our customers.
|
Code Name
|
Phase conductor
|
Bare Neutral Message
|
Nominal Weight ( kg/km )
|
Allowable Ampacity
|
|||||
|
Size & No.of wires
|
Insulation Thick
(mm)
|
Nominal Dia.(mm)
|
Size & No.of wires
|
Rated Strength (kg)
|
XLPE
|
Aluminum
|
( A )
|
||
|
Bare
|
OD
|
||||||||
|
AAC
|
|||||||||
|
Pekingese
|
6-Solid
|
1.14
|
4.1
|
6.4
|
6-7
|
255
|
20.8
|
72.9
|
78
|
|
Collie
|
6-7
|
1.14
|
4.6
|
6.9
|
6-7
|
255
|
23.8
|
72.9
|
78
|
|
Cocker
|
6-7
|
1.52
|
4.6
|
7.7
|
6-7
|
255
|
32.7
|
72.9
|
78
|
|
Dachshund
|
4-Solid
|
1.14
|
5.2
|
7.5
|
6-7
|
400
|
26.8
|
114.6
|
103
|
|
Spaniel
|
4-7
|
1.14
|
5.9
|
8.2
|
6-7
|
400
|
29.8
|
116.1
|
103
|
|
Cairn
|
4-7
|
1.52
|
5.9
|
8.9
|
6-7
|
400
|
40.2
|
116.1
|
103
|
|
Doberman
|
2-7
|
1.14
|
7.4
|
9.7
|
2-7
|
612
|
38.7
|
184.5
|
136
|
|
Airedale
|
1-19
|
1.52
|
8.4
|
11.5
|
1-7
|
-
|
56.5
|
233.6
|
158
|
|
Basset
|
1/0-7
|
1.52
|
9.3
|
12.4
|
1/0-7
|
903
|
64
|
294.7
|
182
|
|
Malemure
|
1/0-19
|
1.52
|
9.4
|
12.5
|
1/0-7
|
903
|
64
|
294.7
|
182
|
|
AAAC
|
|||||||||
|
Chihuahua
|
6-Solid
|
1.14
|
4.1
|
6.4
|
6-7
|
499
|
20.8
|
72.9
|
78
|
|
VIzsla
|
6-7
|
1.14
|
4.6
|
6.9
|
6-7
|
499
|
23.8
|
72.9
|
78
|
|
Harrier
|
4-Solid
|
1.14
|
5.2
|
7.5
|
4-7
|
798
|
26.8
|
116.1
|
103
|
|
Whippet
|
4-7
|
1.14
|
5.9
|
8.2
|
4-7
|
798
|
29.8
|
116.1
|
103
|
|
Schnauzer
|
2-7
|
1.14
|
7.4
|
9.7
|
2-7
|
1270
|
38.7
|
184.5
|
136
|
|
Afghan
|
1/0-7
|
1.52
|
9.3
|
12.4
|
1/0-7
|
2023
|
64
|
296.1
|
182
|
|
Hocler
|
1/0-19
|
1.52
|
9.4
|
12.5
|
1/0-7
|
2023
|
64
|
296.1
|
182
|
|
ACSR
|
|||||||||
|
Setter
|
6-Solid
|
1.14
|
4.1
|
6.4
|
6/6/01
|
540
|
20.8
|
72.9
|
78
|
|
Shepherd
|
6-7
|
1.14
|
4.6
|
6.9
|
6/6/01
|
540
|
23.8
|
72.9
|
78
|
|
Retriever
|
6-7
|
1.52
|
4.6
|
7.7
|
6/6/01
|
540
|
32.7
|
72.9
|
78
|
|
Eskimo
|
4-Solid
|
1.14
|
5.2
|
7.5
|
4/6/01
|
844
|
26.8
|
114.6
|
103
|
|
Terrier
|
4-7
|
1.14
|
5.9
|
8.2
|
4/6/01
|
844
|
29.8
|
116.1
|
103
|
|
Yorkshirc
|
4-7
|
1.52
|
5.9
|
8.9
|
4/6/01
|
844
|
40.2
|
116.1
|
103
|
|
Chow
|
2-7
|
1.14
|
7.4
|
9.7
|
2/6/01
|
1293
|
38.7
|
184.5
|
136
|
|
Labrador
|
1-19
|
1.52
|
8.4
|
11.5
|
1/6/01
|
1610
|
56.5
|
233.6
|
158
|
|
Bloodhound
|
1/0-7
|
1.52
|
9.3
|
12.4
|
1/0-6/1
|
1987
|
64
|
294.7
|
182
|
|
Bull
|
1/0-19
|
1.52
|
9.4
|
12.5
|
1/0-6/1
|
1987
|
64
|
294.7
|
182
|
Duplex Service Drop
ABC Cable Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum.
Triplex Service Drop
ABC Cable Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
Quadruplex Service Drop
ABC Cable Applications:Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
4: Product certification

5: About us
We have advanced equipment and excellent team, our goal is to provide the best quality cables to create more value for our customers all over the world.
Since the establishment of our company, our philosophy of strict management and careful production of every meter of cable has given us a good reputation among all customers at home and abroad.
Enterprise main products are: electrical wire, battery cable, control cable, power cable, branch cable, shielded cable welding cable, rubber cables, solar cable, etc., can also according to customer demand production design and other requirements of special cable. In recent years, companies with advanced technology and modern production and testing equipment, tightly grasp the policy direction, combined with dynamic industry product development, development of market capacity, long life cycle, high value-added new products, has introduced various types of low smoke zero halogen flame retardant and fireproof cables, Marine cables, automotive wire, etc., make the enterprise products more in line with the demand of the market.
Service:
1: Quick Response --All inquiries on our products will be replied within 24 hours.
2: Professional Quotation --All pricing will be made on customers' detailed specifications & requirements.
3: Design for you--We can design drums, cartons for customer's require.
4: Stable Quality --All materials and products passed restrict QC procedures.
5:Good After-sales Service
--All Documents will be issued according to clients' instructions, to save troubles from local customs.
--Any complaint to quality or packing issued will be responded, and terminated with proper solutions for clients.
6: Package and Shipping

7: FAQ:
Q: How can I get the Quotation of the products ?
Send your Message to us by E-mail / TradeManager,We'll reply you within 1 hour in the Working Time.
Q: How does your company do regarding Quality Control ?
1) All raw material we selected the high quality one.
2) Professional & Skilful workers care every details in handling the producing.
3) Quality Control Department specially responsible for quality checking in each process.
Q:Do you provide OEM Project Service ?
OEM & ODM order is warmly welcome and we have fully successful experience in OEM projects.
What's more, our R&D team will give you the professional suggestions.
Q: How Could I get the Sample ?
We are honored to offer you samples,Samples is free provided,but need pay the courier freight.
If you have a courier account, you can send your courier to collect samples.
Q: How long is the Delivery Time ?
1) For Sample: 1-3 Days ;
2) For small Orders: 3-10 Days;
3) For mass Orders: 10-18 Days.
Hot Tags: overhead xlpe insulated aluminum electric abc cable, China overhead xlpe insulated aluminum electric abc cable manufacturers, suppliers, Soft Copper Conducto Flexible Welding Cable, Flat special elevator cable, Building SAA Electric Flat TPS cable, Flexible Copper Conductor Multi core Control Cable, Burglar Security Shielded Alarm Cable, Copper Electrical Low Voltage Power Cable